Parameter Table
Power | 200W | 300W | 400W | 500W | 600W | 800W | 1000W |
Solar panels | ≥200W | ≥300W | ≥400W | ≥500W | ≥600W | ≥800W | ≥1000W |
DC MAX input | 240W | 360W | 480W | 600W | 720W | 960W | 1200W |
DC input range | 10.8-28V | ||||||
MPPT Voltage | 15.5-20VDC | ||||||
DC MAX current | 15A | 20A | 25A | 30A | 35A | 45A | 60A |
AC MAX output | 230W | 330W | 430W | 550W | 630W | 830W | 1100W |
AC output range | 120VAC(90-140VAC) or 230VAC(190-260VAC) | ||||||
Frequency range | 50Hz/60Hz(Auto control) | ||||||
Power Factor | >97.5% | ||||||
THD | <5% | ||||||
Phase Shift | <2% | ||||||
Efficiency | 120VAC(90-140VAC) | ||||||
Peak Efficiency | 90% | 90% | 88% | 87% | 85% | 83% | 81% |
Stable Efficiency | 88% | 87% | 86% | 84% | 84% | 81% | 79% |
Efficiency | 230VAC(190-260VAC) | ||||||
Peak Efficiency | 91% | 90% | 88% | 87% | 85% | 85% | 82% |
Stable Efficiency | 89% | 88% | 87% | 85% | 85% | 83% | 80% |
Protection | Islanding; Short-circuit; converse connection; Low Voltage; Over Voltage; Over temperature Protection | ||||||
Work Temperature | ‘-25℃-65℃ | ||||||
Work Humidity | 0%~90%RH non-condensing | ||||||
Grade of Waterproof | Indoor design | ||||||
Show | 1 Red and 1 Green | ||||||
Cooling | Fan | ||||||
Stand-by Power | 2-3W | ||||||
EMC | EN61000-6-3:2007 EN61000-6-1:2007 | ||||||
Grid Disturbance | EN 50178+EN 62109-1+VDE0126-1-12 | ||||||
Grid Detection | DIN VDE 1026 UL1741 | ||||||
Certificate | CE |